济南这边改管道、换阀,非常烦的不是阀贵,是阀到货往地上一摆——孔距对不上、结构长度差一截、螺栓眼转半圈才通。工人举着扳手干瞪眼,工期就卡在这几毫米上。买良工也好、别的牌也好,图纸上只写“DN100 PN16 闸阀”是不够的,到货前得把这几个“现场尺寸”先锁死。

The most troublesome thing about changing pipelines and valves in Jinan is not that the valves are expensive, but that the valves are thrown on the ground when they arrive - the hole spacing cannot be matched, the structural length difference is one section, and the bolt holes need to be rotated half a circle before they can be connected. The worker held a wrench and stared blankly, and the construction period was stuck in these few millimeters. Whether it's buying a good job or other brands, it's not enough to only write "DN100 PN16 gate valve" on the drawing. These "on-site dimensions" need to be locked before arrival.

先量法兰孔距和螺栓孔数。同为 DN100、PN16,国标 GB/T 9119 是 8 个 Ø22 孔、孔中心圆 Ø162;美标 ANSI 150lb 是 8 个 Ø22 孔、孔中心圆 Ø171;日标 JIS 10K 又是另一套。老管线改造非常常踩这个坑——图纸抄的是老外设备接口,采购按国标下单,到货根本穿不进螺栓。量的时候别只报 DN,拿卷尺量孔中心圆直径 + 孔数 + 孔径三个数,比报型号稳。

Measure the distance between flange holes and the number of bolt holes first. Both DN100 and PN16, the national standard GB/T 9119 has 8 Ø 22 holes with a hole center circle Ø 162; The American standard ANSI 150lb consists of 8 Ø 22 holes with a hole center circle Ø 171; The Japanese standard JIS 10K is another set. The most common pitfall in the renovation of old pipelines is that the drawings are copied from foreign equipment interfaces, and the procurement orders are placed according to national standards, but the bolts cannot be penetrated when they arrive. When measuring, don't just report DN. Use a tape measure to measure the diameter of the center circle of the hole, the number of holes, and the diameter of the hole, which is more stable than reporting the model.

截止阀02

再看结构长度(L 值)。同口径同压力,闸阀、截止阀、球阀长度不一样;同是闸阀,国标短系列、长系列、美标 API 600 又差一截。更换旧阀时,别拆了再量,先量两片法兰内侧面净距,再选对应 L 值的阀,不然要么装不进、要么法兰硬掰变形。

Take another look at the length of the structure (L value). Same diameter and pressure, gate valve, globe valve, and ball valve have different lengths; Both are gate valves, with a gap between the national standard short series, long series, and American standard API 600. When replacing an old valve, do not disassemble and measure again. First measure the net distance between the inner sides of the two flanges, and then select the valve corresponding to the L value. Otherwise, it will either not fit in or the flange will be deformed due to hard bending.

密封面形式也得对上老管。突面 RF、凹凸面 MFM、环连接面 RJ,老系统焊的是哪种就配哪种。突面配凹凸法兰,垫片压不住,试压必渗。

The sealing surface form also needs to match the old pipe. RF with convex surface, MFM with concave convex surface, RJ with ring connection surface, the old system is equipped with whichever one is welded. The protruding surface is equipped with a concave convex flange, and the gasket cannot press it, so it will leak during pressure testing.

还有个隐账:螺栓材质。室外管廊、海边、化工区,别用普通镀锌螺栓配不锈钢阀,电偶腐蚀半年就烂头;316 阀体配 A4-70 螺栓,碳钢阀配 35CrMoA 调质螺栓,合同里写清,别让供货商“顺手配”。

There is another hidden account: bolt material. Do not use ordinary galvanized bolts with stainless steel valves for outdoor pipe galleries, seaside areas, and chemical industrial zones, as galvanic corrosion can cause head failure in six months; The 316 valve body is equipped with A4-70 bolts, and the carbon steel valve is equipped with 35CrMoA quenched and tempered bolts. The contract clearly states this, so do not let the supplier "install it easily".

到货别只数箱数。拿卷尺复核法兰孔距、结构长度、阀体钢印炉号与材质单批号,试压报告看壳体 1.5 倍、密封 1.1 倍,气体工况补气泡级气密。济南本地有实体网点,急修能现场比对旧阀量尺寸,比跨省寄样快一天是一天。

Don't count only the number of boxes upon arrival. Use a tape measure to double check the flange hole spacing, structural length, valve body steel seal furnace number, and material batch number. Check the pressure test report to see that the shell is 1.5 times larger and the seal is 1.1 times larger. Add bubble level airtightness for gas working conditions. There are physical branches in Jinan, and emergency repairs can compare the size of old valves on site, which is one day faster than sending samples across provinces.

阀门这行,型号对只是入场券,接口尺寸对得上才叫能装。孔距、L 值、密封面、螺栓级,四样咬住,现场才不会“阀到了、装不上”。

In the valve industry, matching the model is just an admission ticket, and only when the interface size matches can it be installed. The hole spacing, L value, sealing surface, and bolt level should be clamped together in order to avoid the situation of "valve arriving and unable to be installed" on site.

本文由上海良工阀济南销售处友情奉献。更多有关的知识请点击:http://www.jnlgvf.com 我们将会对你提出的疑问进行详细的解答,欢迎你登录网站留言.

This article is a friendly contribution from the Jinan sales office of Shanghai Lianggong Valve. For more information, please click: http://www.jnlgvf.com We will provide detailed answers to your questions. You are welcome to log in to our website and leave a message

下一条:

热销产品:   执行驱动装置 通用工业阀门 冶金工业阀门 水利水务阀门 石油化工阀门 电力电站阀门 核电军工阀门

上海良工阀门山东济南销售处 网站备案号:鲁ICP备2021030403号-1    电话:15098929951 座机:0531—85816056 地址:济南天桥区历山北路198号国际五金机电城A区412号 
网址:https://www.jnlgvf.com/